Thermostat Housing (G2323060): Installation
- Install the new O-ring seal.
Renew Part: Thermostat housing seal(s) Quantity: 1 .
- Install the thermostat housing.
- Install and tighten the 2 bolts.
Torque : 12 Nm
- Install the new O-ring seal.
- Connect the coolant hose.
- Install the wiring harness clip.
-
- Install the coolant hose.
- Install the 2 clamps.
- Connect the 2 coolant hoses.
- Connect the electrical connector.
-
- Install the wiring harness clip.
- Install the wiring harness into the clip.
-
- Install the A/C compressor bracket.
- Install and tighten the 4 bolts.
Torque : 25 Nm
-
- Install the A/C pipe.
- Install and tighten the bolt.
Torque : 9 Nm
- Install the A/C
compressor.
Refer to: AIR CONDITIONING COMPRESSOR - INGENIUM I6 3.0L PETROL
- Vacuum fill the cooling system.
Refer to: COOLING SYSTEM PARTIAL DRAINING AND VACUUM FILLING
- Connect the startup battery ground cable.
Refer to: STARTUP BATTERY DISCONNECT AND CONNECT