Home >> Land Rover >> 2021 >> Range Rover Velar R-Dynamic HSE >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Engine Cooling INGENIUM I6 3.0L Petrol -- Range Rover Velar/L560 >> Engine Cooling - INGENIUM I6 3.0L Petrol >> Removal And Installation >> Coolant Pump (G3186294) >> Installation

Coolant Pump (G3186294): Installation

    • Install the new O-ring seal.

      Renew Part: Engine coolant pump O-ring seal Quantity: 1 . 

    • Install the coolant pump.
    • Install and tighten the 3 new bolts.

      Renew Part: Coolant pump bolts Quantity: 3 . 

      Torque  : 25 Nm 

    • Connect the 2 electrical connectors.
    • Install the coolant pump pulley.
    • Install the 3 bolts finger tight at this stage.
  1. Install the accessory drive belt.

    Refer to: ACCESSORY DRIVE BELT

  2. Tighten the coolant pump pulley bolts.

    Torque  : 25 Nm 

  3. Install the electric cooling fan and shroud.

    Refer to: ELECTRIC COOLING FAN AND SHROUD 

  4. Fill the engine cooling system with the correct amount of coolant fluid.

    Refer to: COOLING SYSTEM PARTIAL DRAINING AND VACUUM FILLING 

  5. Connect the startup battery ground cable.

    Refer to: STARTUP BATTERY DISCONNECT AND CONNECT