Cooling Module (G2308097): Installation
-
CAUTION: Care must be taken not to damage the component.
With assistance, install the cooling module.
- Connect the 3 left coolant hoses.
- Connect the 3 right coolant hoses.
- Install the new seals.
Renew Part: Condensor to high pressure line O-ring seal Quantity: 2 .
- Connect the Air Conditioning (A/C) pipes.
- Install and tighten the 2 nuts.
Torque : 24 Nm
- Install the new seals.
- Connect the cooling fan electrical connector.
- Install the hood latch panel.
Refer to: HOOD LATCH PANEL .
- Install the coolant pump.
Refer to: COOLANT PUMP - CHARGE AIR COOLER .
- Vacuum fill the cooling system.
Refer to: COOLING SYSTEM PARTIAL DRAINING AND VACUUM FILLING .
- Connect the startup battery ground cable.
Refer to: 12V SYSTEM DISCONNECT .
- Recharge the A/C system.
Refer to: AIR CONDITIONING SYSTEM RECOVERY, EVACUATION AND CHARGING .