Supplementary Restraint System
The wiring used for a SRS firing circuit repair must be 0.5 mm2 (0.00078 inch2 ) cross sectional area. Replace Both the affected male and female terminals in the connector using pre-terminated leads. Installation of SRS connectors, cut the wiring harness at a suitable point as close as possible to the damaged connector (destroy the removed connector). Identify the correct new connector from the SRS firing circuit wiring harness repair kit or recommended overlay and cut to a suitable length. Install to the SRS firing circuit wiring harness using the connecting splices supplied and a replaced pre-terminated lead which can be identified from the ERL wire chart information.
Follow the repair procedure detailed above, taking into account the staggering of connecting splices and the number of twists. The whole repair should then be covered with yellow heat shrink sleeve supplied to act as SRS firing circuit wiring repair location/identification. The repair authentication label must be completed by the authorized technician conducting the repair and approved by their supervisor. The label must then be secured around the harness adjacent to or at a suitable point as close as possible to the location of the repair.
Care and neatness are essential requirements in making a perfect repair.