Solvent Retention
NOTE:
Alternative Terminology: Boil, pits, bubbles, pin-holes, boiling, solvent boil, solvent shock and air bubbles.
Description
Bubbles of solvent retained in the clear coat, usually close to the surface and in localized areas, of a size between 0.5 and 1 mm (0.020 and 0.040 in.) diameter. May initially be apparent as black dots, but close examination will reveal the depth at which they are held in the clear coat.
Warranty Related Cause
- Fault with manufacturing process.
Non-warranty Related Cause(s)
- None.
Rectification Process
- Determine if exception is permissible or not permissible. For additional information, Refer to: COSMETIC ACCEPTANCE STANDARDS .
- Permissible exception does not require a repair so should be passed as CA.
- Repair any not permissible exceptions by re-painting as required.