Diagnostic Module Tank Leakage Pump (G2340248): Installation
WARNING: This page is about a different variant/trim than selected.
-
- Install the Diagnostic Module Tank Leakage (DMTL) pump to the DMTL bracket.
- Install and tighten the 3 screws.
Torque : 1.8Nm
-
- Install the DMTL pump and evaporative emission canister bracket to the evaporative emission canister.
- Install and tighten the 2 bolts.
Torque : 4.5Nm
-
- Install the 2 vacuum hoses to the DMTL pump.
- Install and tighten the 2 bolts.
Torque : 4.5Nm
-
- Connect the vacuum hoses to the evaporative emission canister.
- Install the evaporative emission canister.
- Install and tighten the 2 nuts.
Torque : 9Nm
- Install and tighten the bolt.
Torque : 9Nm
-
- Install the vacuum hose to the DMTL filter.
- Connect the electrical connector and install the wiring harness.
- Install the left rear wheel arch liner.
Refer to: REAR FENDER SPLASH SHIELD .
- Connect the startup battery ground cable.
Refer to: SPECIFICATIONS .