Crankshaft Pulley - INGENIUM I4 2.0L Petrol - PHEV (G2748106): Removal
- This procedure contains some variation in the illustrations depending on the vehicle specification, but the essential information is always correct.
- This procedure contains illustrations showing certain components removed to provide extra clarity.
- Raise and support the vehicle on a suitable 2 post lift.
Refer to: JACKING AND LIFTING
- Disconnect the 12 V system.
Refer to: 12V SYSTEM DISCONNECT AND CONNECT
-
WARNING: JLR Electric Vehicle Competent Person (EVCP) trained technicians only.
This procedure involves work on components associated with the High Voltage (HV) system. Only technicians qualified to EVCP level or higher are allowed to do this procedure. It is mandated that all technicians involved with the steps in this procedure have read and understood the Electric Vehicle (EV) Safety Rules.
Refer to: DESCRIPTION AND OPERATION .
- Remove the Belt Integrated Starter Generator (BISG) belt.
Refer to: BELT INTEGRATED STARTER GENERATOR DRIVE BELT - INGENIUM I4 2.0L PETROL - PHEV
Assemble the special tools as illustrated.
Special Tool(s): JLR-303-1630 , JLR-303-1686
Install the special tools.
Special Tool(s): JLR-303-1630 , JLR-303-1686
Remove and discard the 4 bolts.
- Remove the special tools.
Special Tool(s): JLR-303-1630 , JLR-303-1686
- Remove the crankshaft pulley.
- Remove the special tools.
- Install the special tool.
Special Tool(s): JLR-303-1628
- Use the special tool to rotate the crankshaft front seal 35° in a counter clockwise direction.
- Remove and discard the crankshaft front seal.
- Install the special tool.