Electric Thermostat (G2417536): Installation
- Install the new O-ring seal.
Renew Part: Thermostat housing seal(s) Quantity: 1 .
- Install the electric thermostat.
- Install and tighten the 4 bolts.
Torque : 12 Nm
- Install the new O-ring seal.
- Connect the 2 electrical connectors to the electric thermostat.
- Connect the engine coolant lower hose to the electric thermostat.
-
- Connect the engine coolant front hose to the electric thermostat.
- Secure the 2 clips.
-
- Install and connect the purge valve pipe on both sides.
- Secure the 2 clips.
-
- Secure the 2 clips.
- Install the engine coolant rear hose.
-
CAUTION: Make sure that the clips are correctly located.
- Install the engine coolant upper hose.
- Secure the clip.
-
- Install the Noise, Vibration and Harshness (NVH) pad.
- Install the 2 clips.
- Install the fastener.
- Install the left secondary bulkhead panel.
- Fill the engine cooling system with the correct amount of coolant fluid.
Refer to: COOLING SYSTEM PARTIAL DRAINING AND VACUUM FILLING
- Install the engine cover.
Refer to: ENGINE COVER - INGENIUM I4 2.0L PETROL
- Connect the startup battery ground cable.
Refer to: 12V SYSTEM DISCONNECT AND CONNECT