Roof Opening Panel Blind/Roof Opening Panel Glass Faults - Remedial Actions
NOTE:
If the roof opening panel blind is de-normalized the roof opening panel glass cannot open (roof opening panel blind position is not known). If the roof opening panel glass is de-normalized the roof opening panel blind cannot close (roof opening panel glass position is not known)
FAULT TYPE SPECIFICATION
| Fault Type | Remedial Action |
|---|---|
|
Check the body control module for related DTCs and refer to the relevant DTC index. Check the operation of the relevant switches and circuits and rectify as required. After rectification of any faults, re-initialize the roof opening panel blind/roof opening panel glass as detailed below |
|
Check the body control module for related DTCs and refer to the relevant DTC index. Check the operation of the relevant switches and circuits and rectify as required. After rectification of any faults, re-initialize the roof opening panel blind/roof opening panel glass as detailed below |
|
Check the guide rails and mechanism for any signs of damage or debris and rectify as required. After rectification of any faults, re-initialize the roof opening panel blind/roof opening panel glass as detailed below. If there is no sign of debris or mechanical damage, check whether the roof finishers are fitted too tightly to the sunroof rear panel. Remove finishers, loosen clips and move outboard 1mm, re-tighten clips and refit finishers. Re-initialize the roof opening panel blind/roof opening panel glass as detailed below |
|
Check the operation of the relevant switches and circuits and rectify as required. After rectification of any faults, re-initialize the roof opening panel blind/roof opening panel glass as detailed below |