Home >> Land Rover >> 2019 >> Range Rover Sport HSE Dynamic >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 28 (Fuel Charging And Controls - Turbocharger - TDV6 3.0L Diesel -- Range Rover Sport/L494) >> Fuel Charging And Controls - Turbocharger - TDV6 3.0L Diesel >> Description And Operation >> Turbocharger (G1868446) >> Operation >> Shut-Off Valve Control

Shut-Off Valve Control

WARNING: This page is about a different variant/trim than selected.

Turbine intake shut-off valve:  If vacuum is released from the turbine intake shut-off valve it will default to the closed position. The turbine intake shut-off valve position sensor will inform the ECM, which will initiate mono-turbo mode, restrict engine performance and record a DTC.

Charge air shut-off valve:  If vacuum is released from the charge air shut-off valve it will default to the closed position. In the default position, the ECM initiates mono-turbo operation and restricts engine torque. A DTC will also be recorded in the ECM.