LEMON Manuals: Even more car manuals for everyone
Home >> Land Rover >> 2018 >> Range Rover Velar Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 23 (Electronic Engine Controls - V6 S/C 3.0L Petrol -- Range Rover Velar/L560) >> Electronic Engine Controls - V6 S/C 3.0L Petrol >> Diagnosis And Testing >> Electronic Engine Controls - V6 S/C 3.0L Petrol (G2435813) >> Heated Oxygen Sensor Live Data Signals

Heated Oxygen Sensor Live Data Signals

WARNING: This page is about a different variant/trim than selected.
PID DESCRIPTION ACTION
BANK 1 
Live Data signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 1 sensor 1 
0x03A1 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 1 Using the manufacturer approved diagnostic system check the live data signal. The signal is a duty cycle displayed in % varying between limits
0xF434 Oxygen Sensor Current Bank 1 sensor 1 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in mA varying between limits
Live Data signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 1 sensor 2 
0x03A2 Oxygen Sensor (O2S) Heater Duty Cycle Bank 1 Sensor 2 Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF415 Oxygen Sensor Output Voltage Bank 1 - sensor 2 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits
Live Data signal for Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 1 sensor 3 
0x03A3 Oxygen sensor heater duty cycle - Bank 1 sensor 3 Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF416 Oxygen Sensor Output Voltage Bank 1 - sensor 3 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits
BANK 2 
Live Data signal for Heated Oxygen Sensor (HO2S) - Pre catalyst - Bank 2 sensor 1 
0x03A4 Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 1 Using the manufacturer approved diagnostic system check the live data signal. The signal is a duty cycle displayed in % varying between limits
0xF438 Oxygen Sensor Current Bank 2 sensor 1 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in mA varying between limits
Live Data signal for Heated Oxygen Sensor (HO2S) - Mid catalyst - Bank 2 sensor 2 
0x03A5 Oxygen Sensor (O2S) Heater Duty Cycle Bank 2 Sensor 2 Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF419 Oxygen Sensor Output Voltage Bank 2 - sensor 2 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits
Heated Oxygen Sensor (HO2S) - Post catalyst - Bank 2 sensor 3 
0x03A6 Oxygen sensor heater duty cycle - Bank 2 sensor 3 Using the manufacturer approved diagnostic system check the live data signal. The signal is a pulse width modulated signal digital output operating between 0 and 1
0xF41A Oxygen Sensor Output Voltage Bank 2 - sensor 3 Using the manufacturer approved diagnostic system check the live data signal. The signal is displayed in volts varying between limits