Diagnostic Routines
WARNING: This page is about a different variant/trim than selected.
| ROUTINE DESCRIPTION |
ROUTINE ACTION |
| Diesel exhaust fluid level check |
To see current DEF
level and then show the technician the required amount to top-up the tank if required |
| Reset selective catalyst reduction start inhibit |
To Reset Selective Catalyst Reduction (SCR) Inducement System Start Inhibit |
| Reset selective catalyst reduction quality monitor |
To Reset SCR
Quality Monitor |
| SCR
Dosing Module Test |
This cluster of routines tests:
- The pattern of DEF
injected from the dosing module as there is often a build-up of residue around the actual injector
- The Dynamic Behavior - Tests the quantity of DEF
delivered with the injector opened for a given period of time
- The Static Reductant Dosing Quantity - This routine tests the quantity of DEF
delivered against an expected value
- Flushes the Dosing module (DEF
Injector) to remove any crystallization or contamination
|
| Diesel exhaust fluid injection pump replacement |
To Reset DEF
Pump Offset Calibration |
| Diesel exhaust fluid tank level sensor replacement |
To Reset DEF
Volume Using Sensed Tank Level |
| Diesel exhaust fluid prime and pressure test |
- Selective reductant catalyst system end of line first fill and pressure test routine. This routine will prime and test the system
- This routine attempts to pressurize the system to 6 bar/87 psi. If it does not achieve this pressure within a predetermine time it may open the dosing module slightly to release any air from the system. This routine should not be used as a diagnostic function for testing the dosing module
|