Possible Causes
WARNING: This page is about a different variant/trim than selected.
NOTE:
To monitor for too high temperature in the turbine housing; component protection. Temperature sensor temperature above threshold (899.96°C)
- The powertrain control module measured a signal voltage above a specified range but not necessarily a short circuit to power, gain too high
- Other related DTCs
- Airpath
- Turbocharger
- EGR
- Fuel system
- Turbocharger housing mechanical integrity
- Fuel injector (s) mechanical integrity
- Cylinders 1, 2 and 3
- Exhaust gas temperature sensor - Turbine temperature sensor circuit short circuit to ground, short circuit to power, open circuit, high resistance
- Connector is disconnected, connector pin is backed out, connector pin corrosion
- Exhaust gas temperature sensor - Turbine temperature sensor failure