DTC P2BAF-04: NOx System Driver Inducement Active - System internal failures: Action
WARNING: This page is about a different variant/trim than selected.
- Vehicle Conditions to enable DTC Logging Strategy
- Ignition on
- The fault path responsible for the inducement level may require driving cycle conditions
- Prioritised Checks to Perform
- Diagnosis of this DTC may require using the Jaguar Land Rover approved diagnostic equipment check datalogger signals
- 0x05C1 Reductant Tank Fluid Level
- Check and correct diesel exhaust fluid level
- Check powertrain control module for related DTCs and refer to relevant DTC index
- Using the Jaguar Land Rover approved diagnostic equipment, clear the DTCs and retest
- The inducement system will clear automatically upon acknowledgment of repair by the OBD system