Reservoir Pressure Switch: Installation
- Apply Loctite 572 to thread of pressure switch.
- Fit pressure switch and tighten to 23 N.m (17 ft. lbs.).
- Connect multi-plug and battery.
- Start engine to re-pressurize system.
- Attain standard ride height.
- Leak test pressure switch. See LEAK TEST PROCEDURE under TROUBLE SHOOTING.