Circuit Inspection
| Inspection Item | Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |||
| Open in circuit inspection (ICU ↔ SRSCM) |
|
ICU connector | 17 (P-CAN high) | SRSCM connector | 36 (P-CAN high) | Approx. below 1Ω |
| ICU connector | 18 (P-CAN low) | SRSCM connector | 35 (P-CAN low) | Approx. below 1Ω | ||
| Open in circuit inspection (ICU ↔ PBS) |
|
ICU connector | 33 (signal) | PBS connector | 1 (signal) | Approx. below 1Ω |
| Short in circuit inspection (PBS ↔ Chassis ground) |
|
PBS connector | 1 (signal) | Chassis ground | - | ∞ (infinity)Ω |
| Open in circuit inspection (PBS ↔ Chassis ground) |
|
PBS connector | 2 (ground) | Chassis ground | - | Approx. below 1Ω |
| Oscilloscope (PBS) |
|
PBS connector | 1 (signal) | Chassis ground | - | Fig.1 |
Good
- Carefully re-do this troubleshooting guide steps.
- If problem still occurs, replace SRSCM and then Go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If problem still occurs, replace SRSCM main harness and then Go to "VERIFICATION OF REPAIR " procedure.