Squib Circuit Inspection: Notes
NOTE:
If dummy and dummy adaptor are not able to be prepared, use a 2Ω resistor.
- Ignition "OFF".
- Disconnect the 12V battery (-) cable and wait for 5 minute or more.
- Remove the DSAB module and connect the dummy and dummy adapter to the DSAB module connector.
- Connect the 12V battery (-) cable and ignition "ON" and wait for 30s or more.
- Connect KDS to Data Link Connector (DLC) and clear DTC with KDS and diagnose again.
- Are any DTCs stored in the system?
Good
- Go to "MAIN HARNESS CIRCUIT INSPECTION " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.