LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2024 >> Telluride SX X-Line >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> Refrigerant Recovery/Recycling/Charging/Vacuum/Leak Test >> Refrigerant Recovery/Recycling/Charging/Vacuum (R-1234yf) >> Refrigerant charge

Refrigerant charge

  1. Replenish the amount of discharged compressor oil by using R-1234yf recovery/recycling/charging equipment while the high pressure valve is opened after evacuating the air conditioner system.
    NOTE: If additional oil is not added when charging the refrigerant, the lubricity deteriorates due to insufficient oil in the system, which cause problem such as compressor sticking.
  2. Charge the refrigerant with specified amount while the high-pressure valve open by using the R-1234yf recovery/recycling/charging equipment and then close the high-pressure valve.

    Regulated refrigerant amount:  950 ± 25 (33.51 ± 0.88)

    NOTE: Do not overcharge the refrigerant as there is a risk of damage to the compressor.
  3. Check that the refrigerant is not leaking from the system with leak detector. (Refer to REFRIGERANT LEAK TEST )