Precaution (R-1234yf): Notes
WARNING:
- The R-1234yf liquid refrigerant is flammable gas. The gas reduces oxygen available for breathing and causes asphyxiation in high concentrations. The victim will not realize that he/she is suffocating.
- Inhalation may cause central nervous system effects and may cause drowsiness and dizziness.
- Ingestion may cause gastrointestinal discomfort. It may cause skin irritation, eye irritation and respiratory tract irritation. Do not breathe vapor. Avoid contact with skin, eyes and clothing.
CAUTION:
In case of emergency, the following precautions must be observed: First aider needs to protect himself. Take off all contaminated clothing immediately.
- Inhalation: Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Use oxygen as required, provided a qualified operator is present. Call a physician.
- Skin contact: After contact with skin, wash immediately with plenty of water. Rapid evaporation of the liquid may cause frostbite. If there is evidence of frostbite, bathe (do not rub) with lukewarm (not hot) water. If water is not available, cover with a clean, soft cloth or similar covering. Call a physician. Wash contaminated clothing before re-use.
- Eye contact: Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. In case of frostbite water should be lukewarm, not hot. Call a physician.
- Ingestion: Unlikely route of exposure. As this product is a gas, refer to the inhalation section. Do not induce vomiting without medical advice. If conscious, drink plenty of water. Never give anything by mouth to an unconscious person. Call a physician immediately.
CAUTION:
When handling the refrigerant, the following precautions must be observed;
- Handle with care.
- Wear personal protective equipment.
- Do not breathe vapor.
- Avoid contact with skin, eyes and clothing.
- Ensure that eyewash stations and safety showers are close to the workstation location.
- Use only in well-ventilated areas.
- Protect from sunlight and do not expose to temperatures exceeding 52°C (125°F).
- Follow all standard safety precautions for handling and use of compressed gas cylinders.
- Use authorized cylinders only.
- Protect cylinders from physical damage.
- Do not puncture or drop cylinders, expose them to open flame or excessive heat.
- Do not remove screw cap until immediately ready for use.
- Always replace cap after use.
- Container is hazardous when empty.
- Prevent the creation of flammable or explosive concentrations of vapor in air and avoid vapor concentration higher than the occupational exposure limits.
- Keep product and empty container away from heat and sources of ignition.
- Do not pressurize, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition.
- Take measures to prevent the build up of electrostatic charge.
- Electrical equipment should be protected to the appropriate standard.
- Use explosion-proof equipment.
- No sparking tools should be used.
- No smoking.
CAUTION:
- When storing the refrigerant, the following precautions must be observed;
- Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 52°C (125°F). Do not pierce or burn, even after use.
- Keep containers tightly closed in a dry, cool and well-ventilated place.
- Keep away from heat and sources of ignition.
- Storage rooms must be properly ventilated.
- Ensure adequate ventilation, especially in confined areas.
- Protect cylinders from physical damage.
- Store away from incompatible substances.
- Store in original container.
WARNING:
- Un-controlled release of R-1234yf refrigerant in the work area may result in high concentrations of R-1234yf that can be flammable. Servicing of R-1234yf systems shall only be done in well ventilated work areas.
- When servicing, maintaining or repairing A/C systems using flammable refrigerants (mildly flammable or higher) the work place shall meet all applicable national, regional or local regulations for work place safety as related to high pressure or flammable gases.
CAUTION:
- Avoid breathing any refrigerant vapor and lubricant mist. To remove refrigerant from a A/C system, use service equipment designed for recovery and removal that is certified to meet the requirements of the appropriate SAE Standards.
- Do not increase pressure, in any R-134a, or R-1234yf mobile A/C system with shop air or another refrigerant such as HCFC-22 (R-22) for leak checking, due to potential chemical reactions, flammability of air/R-134a at elevated pressure, contamination of the system, and possible structural damage to the system.
- To prevent an accumulation of refrigerant in case of a major refrigerant leak, open vehicle windows and doors when charging an A/C system
- To prevent accidental release of refrigerant and minimize safety concerns, the installation of any refrigerant service equipment to the vehicle shall only be done with the engine off and after the refrigerant high side pressure has been reduced (approximately 2 to 3 min).
CAUTION:
- The proper handling procedures should be followed for all refrigerants as designated by the refrigerant manufacturer's Material Safety Data Sheet (MSDS).
- Service personnel shall be aware of the high pressure relief valve location when servicing the vehicle. Service personnel shall not be under the vehicle when charging the refrigerant system due to potential sudden release of the high pressure relief valve.