Removal & Installation: Installation
- Install in reverse order of removal.NOTE:
- When installing a new condenser, replenish the compressor oil.
- Replace the O-rings at each connection with new ones, and apply a few drops of compressor oil (refrigerant oil) to the O-rings before connecting hoses or lines. To avoid leakage of refrigerant, use the specified O-ring.
- Be careful not to impact the radiator and condenser pin when installing the condenser.
- Make sure that the lower mounting of the condenser is correctly installed on the lower bracket of the radiator.
- Perform refrigerant Leak Test/Vacuum/Charging.
(Refer to Air conditioning System - "REFRIGERANT RECOVERY/RECYCLING/CHARGING/VACUUM/LEAK TEST ")