LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2024 >> Telluride SX X-Line >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System Diagnosis >> DTC B1241-11: Evaporator Sensor Short (Low) >> Component Inspection

Component Inspection

Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
  1. Ignition "OFF".
  2. Disconnect the electrical connector(s) from the concerned component.
Evaporator sensor (component side) 2 (signal) Evaporator sensor (component side) 1 (ground) Table1
EVAPORATOR SENSOR SPECIFICATION

Ambient Temperature (°C/°F) Resistance (kΩ)
-10/-50 43.3
0/32 27.6
10/50 18
20/68 12.1
30/86 8.3
40/104 5.8

Good 

No Good