LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2024 >> Telluride SX X-Line >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Wireless Power Charger Diagnosis >> DTC B1603-00: CAN Bus Off >> DTC Information >> Wireless Power Charger (WPC) System Protection

Wireless Power Charger (WPC) System Protection

Item Condition Status
Protects against low/high voltage Protects and stops charging under 8.5V or over 16.5V LED OFF (Stops operation)
Charges between 9 to 16 volts
Protects against reverse voltage Protects and stops charging in case of reverse voltage LED OFF (Stops operation)
Protects against overcurrent Protects and stops charging in case of detecting 4 amps Amber LED blinks
Protects against overheating Protects and stops charging in case of detecting 167°F (75°C) by internal temperature sensor of wireless charging module Amber LED blinks
Resumes under 158°F (70°C)
Foreign matter (Coins, clips, precious metals, etc.) Protects and stops charging in case of detecting foreign matter (overheating prevention) Amber LED blinks
Prevents frequency interference Protects and stops charging by activating IBU in case door or tailgate is open LED OFF (Stops operation)
Resumes in 3.5s after all doors and tailgate are closed and IBU operation is completed
Alert for contact with mobile phone In case of smart phone on the charging pad when opening the door after ignition "OFF" Displays warning message on the instrument panel (for about 4s)