Module Inspection
| Inspection Item | Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |||
| Power inspection (AVNT ↔ Chassis ground) |
|
AVNT connector | 10, 11, 22, 33 (power) | Chassis ground | - | B+ |
| Open in circuit inspection (AVNT ↔ Chassis ground) |
|
AVNT connector | 1, 12, 13 (ground) | Chassis ground | - | Approx. below 1Ω |
| Power inspection (ICU ↔ Chassis ground) |
|
ICU connector | 1, 2, 3, 4, 17, 26, 31 (power) | Chassis ground | - | B+ |
| Open in circuit inspection (ICU ↔ Chassis ground) |
|
ICU connector | 16, 24 (ground) | Chassis ground | - | Approx. below 1Ω |
Good
- Go to "CAN COMMUNICATION CIRCUIT INSPECTION (M-CAN) " procedure.
No Good
- Repair as necessary and Go to "VERIFICATION OF REPAIR " procedure.