Shift Control Solenoid Valve (28/B) Resistance Inspection
WARNING: This page is about a different variant/trim than selected.
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
ATM solenoid valve (component side) | 14 (power) | ATM solenoid valve (component side) | 23 (28/B) | Approx. 5.0Ω |
Good
- Carefully re-do this troubleshooting guide steps.
- If problem still occurs, replace PCM and then go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.
- If problem still occurs, replace shift control solenoid valve (28/B) and then go to "VERIFICATION OF REPAIR " procedure.