LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2023 >> Sorento X-Line EX >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 23 (Automatic Transaxle System - General Information - 2.5L (VIN C) (Except HEV)) >> Specifications >> Service Data >> Solenoid Valve

Solenoid Valve

WARNING: This page is about a different variant/trim than selected.
Item Specification
Direct control VFS 28/B_VFS Control type N/L (Normal Low)
Control pressure kPa (kgf/cm2 , psi) 0-1, 569.06 (0-16, 0-227.57)
Current (mA) 0-1, 100
Coil resistance (Ω) 5.3 ± 0.3
46/C_VFS Control type N/L (Normal Low)
Control pressure kPa (kgf/cm2 , psi) 0-1, 569.06 (0-16, 0-227.57)
Current (mA) 0-1, 100
Coil resistance (Ω) 5.3 ± 0.3
37R/C_VFS Control type N/L (Normal Low)
Control pressure kPa (kgf/cm2 , psi) 0 - 1, 569.06 (0 - 16, 0 - 227.57)
Current (mA) 0-1, 100
Coil resistance (Ω) 5.3 ±0.3
UD/C_VFS Control type N/H (Normal High)
Control pressure kPa (kgf/cm2 , psi) 0 - 1, 569.06 (0 - 16, 0 - 227.57)
Current (mA) 0-1, 100
Coil resistance (Ω) 5.3 ± 0.3
OD/C & LR/B_VFS Control type N/H (Normal High)
Control pressure kPa (kgf/cm2, psi) 0 - 1, 569.06 (0 - 16, 0 - 227.57)
Current (mA) 0 - 1, 100
Coil resistance (Ω) 5.3 ± 0.3
Indirect control VFS T/CON_VFS Control type N/L (Normal Low)
Control pressure kPa (kgf/cm2, psi) 0-519.75 (0 - 5.3, 0-75.38)
Current (mA) 0-850
Coil resistance (Ω) 5.1 ± 0.3
LINE_VFS Control type N/H (Normal High)
Control pressure kPa (kgf/cm2, psi) 0 - 519.75 (0 - 5.3, 0 - 75.38)
Current (mA) 0 - 850
Coil resistance (Ω) 5.1 ± 0.3
ON/OFF SS-A Control type ON/OFF
Control pressure kPa (kgf/cm2, psi) 0 - 490.33 (0 - 5.0, 0 - 71.12)
Voltage (V) 9-16
Coil resistance (Ω) 10.0 - 11.0