Circuit Inspection
WARNING: This page is about a different variant/trim than selected.
| CAN Communication Line Inspection | |||||
|---|---|---|---|---|---|
| Inspection Condition | (+) Probe | (-) Probe | Reference | ||
| Connector | Terminal | Connector | Terminal | ||
|
ICU connector | 17 (P-CAN high) | Chassis ground | - | Fig.1 |
| ICU connector | 18 (P-CAN high) | Chassis ground | - | ||
|
PCM connector | 6 (P-CAN high) | PCM connector | 7 (P-CAN low) | Approx. 60Ω |
| PCM (component side) | 6 (P-CAN high) | PCM (component side) | 7 (P-CAN low) | Approx. 120Ω | |
| ICU (component side) | 17 (P-CAN high) | ICU (component side) | 18 (P-CAN low) | Approx. 120Ω | |
| ICU connector | 17 (P-CAN high) | Chassis ground | - | ∞ (infinity)Ω | |
| ICU connector | 18 (P-CAN high) | Chassis ground | - | ∞ (infinity)Ω | |
| ICU connector | 17 (P-CAN high) | PCM connector | 6 (P-CAN high) | Approx. below 1Ω | |
| ICU connector | 18 (P-CAN low) | PCM connector | 7 (P-CAN low) | Approx. below 1Ω | |
Good
- Go to "Module Circuit Inspection" procedure.
No Good
- Repair open or short in circuit and then go to "VERIFICATION OF REPAIR " procedure.
| Module Circuit Inspection | |||||
|---|---|---|---|---|---|
| Inspection Condition | (+) Probe | (-) Probe | Reference | ||
| Connector | Terminal | Connector | Terminal | ||
|
ICU connector | 1, 4, 6 (power) | Chassis ground | - | B+ |
|
ICU connector | 13, 25 (ground) | Chassis ground | - | Approx. below 1Ω |
Good
- Go to "COMPONENT INSPECTION " procedure.
- Repair as necessary and then go to "VERIFICATION OF REPAIR " procedure.
No Good
- Repair open or short in circuit and then go to "VERIFICATION OF REPAIR " procedure.