Component Inspection
WARNING: This page is about a different variant/trim than selected.
| EOTS Inspection | |||||
|---|---|---|---|---|---|
| Inspection Condition | (+) Probe | (-) Probe | Reference | ||
| Connector | Terminal | Connector | Terminal | ||
|
EOTS (component side) | 4 (signal) | EOTS (component side) | 1 (ground) | TABLE 1 |
EOTS OF RESISTANCE SPECIFICATION
| Temperature | Resistance (kΩ) | Temperature | Resistance (kΩ) | ||
|---|---|---|---|---|---|
| °C | °F | °C | °F | ||
| -40 | -40 | 125.53 to 136.70 | 60 | 140 | 2.32 to 2.61 |
| -30 | -22 | 93.26 to 104.65 | 70 | 158 | 1.63 to 1.84 |
| -20 | -4 | 63.89 to 71.23 | 80 | 176 | 1.17 to 1.32 |
| -10 | 14 | 41.80 to 46.52 | 90 | 194 | 0.86 to 0.97 |
| 0 | 32 | 26.83 to 30.07 | 100 | 212 | 0.64 to 0.72 |
| 10 | 50 | 17.13 to 19.23 | 110 | 230 | 0.48 to 0.54 |
| 20 | 68 | 11.13 to 12.48 | 120 | 248 | 0.37 to 0.41 |
| 25 | 77 | 9.00 to 10.11 | 130 | 266 | 0.28 to 0.32 |
| 30 | 86 | 7.369 to 8.279 | 140 | 284 | 0.22 to 0.25 |
| 40 | 104 | 4.89 to 5.50 | 150 | 302 | 0.17 to 0.20 |
| 50 | 122 | 3.34 to 3.76 | 160 | 320 | 0.14 to 0.16 |
Good
- Fault is intermittent caused by poor contact in the sensor's and/or PCM's connector or was repaired and PCM memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.