| Case 1 |
DTC Strategy |
- Check the output current and voltage
|
|
| Detecting Condition |
- Charging connector connected
- Charging hybrid battery
- Auxiliary battery voltage: 9 to 16V
|
| Threshold Value |
- When the difference between the OBC output power and the output power command exceeds 15% of the rated output
|
| Case 2 |
DTC Strategy |
- Check the PFC output voltage and PFC output voltage command
|
| Detecting Condition |
- Charging connector connected
- PFC operation with output terminal pre-charging sequence and no LLC operation
- Auxiliary battery voltage: 9 to 16V
|
| Threshold Value |
- When the PFC output voltage is less than 90% of the PFC output voltage command
|
| Case 3 |
DTC Strategy |
- Check the OBC output voltage and OBC output voltage command
|
| Detecting Condition |
- Charging connector connected
- LLC operation with output terminal pre-charging sequence
- Auxiliary battery voltage: 9 to 16V
|
| Threshold Value |
- When the PFC output voltage is less than 90% of the PFC output voltage command
|
| Detecting Time |
|
| MIL On Condition |
|
| Service Lamp On Condition |
|