Home >> Kia >> 2023 >> Sorento Plug-In Hybrid SX Prestige >> Repair and Diagnosis >> Hybrid/Electric Powertrain >> Testing and Diagnosis >> On Board Charger Diagnosis (PHEV) (1 Of 2) >> DTC P0D2A-19: Battery Charger Input Current Too High >> DTC Information >> DTC Detecting Condition

DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Check the input current
  • Electric Vehicle Supply Equipment (EVSE)
  • OBC
Detecting Condition
  • Charging connector connected
  • Slow charging mode (EVSE ready "ON")
  • Auxiliary battery voltage: 9 to 16V
  • S2 switch "ON
Threshold Value
  • OBC input current is greater than 70A
Detecting Time
  • 10 times for 30s
MIL On Condition
  • ON
Service Lamp On Condition
  • ON