DTC Information: DTC Detecting Condition

Item Detecting Condition Possible Cause
DTC Strategy
  • Check the OBC temperature
  • Cooling system
  • Coolant level low
  • Electric water pump (EWP)
  • OBC
Detecting Condition
  • Charging connector connected
  • Slow charging mode (EVSE ready "ON")
  • Auxiliary battery voltage: 9 to 16V
Threshold Value
  • OBC internal temperature is greater than 105°C (221°F)
Detecting Time
  • 2s
MIL On Condition
  • ON
Service Lamp On Condition