DTC Description
WARNING: This page is about a different car, the 2024 Kia Sorento. However, it is still accessible from the selected car via links, so may be relevant.
P0A7700 is set when the up/down switch of the HSG W phase circuit in the HSG inverter power module is turned "ON" at the same time due to error.
WARNING:
Since hybrid vehicles contain a high voltage battery, if the high voltage system or vehicles are handled incorrectly, this might lead to a serious accidents like electric shock and electric leakage.
* Non-compliance with the following instructions can induce death or injury caused by electric shock.
* Non-compliance with the following instructions can induce death or injury caused by electric shock.
- Carefully read and follow service information instructions.
- Wear insulated gloves, safety glasses and use insulated tools for your safety.
- Turn the ignition switch off and disconnect ground cable of auxiliary battery and remove the safety plug.
- Wait for more than 5 minutes so that the inverter capacitor can be naturally discharged.
- Check high voltage terminal on power relay assembly is lower than 30V.
- Per for Resolver adaptation alter the HPCU or the driver motor or the Hybrid Starter Generator (HSG) is replaced or reinstalled.
- When replaced HPCU, Perform air bleeding for HPCU with KDS.