| DTC Strategy |
|
- Poor connector connection
- Faulty IEB module
|
| Enable Condition |
- Ignition "ON"
- Auxiliary battery normal voltage (6.5 ~ 19V)
|
| Threshold Value |
Case 1 (Solenoid valve open) |
- If the valve relay is switched "ON" and the corresponding solenoid driver "OFF" under the conditions below for 165 ms
- ABS/ESC valve: solenoid voltage is less than 2.0V
- BBS valve: drain voltage is less than regulator voltage * 45% for 25 ms
- If the valve relay is switched "ON" and the corresponding solenoid driver "ON" under the condition below for 165 ms
- ABS, ESC valve: target current is less than 1A, solenoid current is less than 0.2A
- BBS valve: target current is less than hold current and than PWM is over than 95%, solenoid current is less than 0.2A
- If the valve relay is switched "ON" and the corresponding solenoid driver "ON" under the condition below for 200 ms
- BBS valve: PWM is over than 95% and than drain voltage is over than 1V
|
| Threshold Value |
Case 2 (Solenoid valve short) |
- If the valve relay is switched "ON" and the corresponding solenoid driver "OFF" under the conditions below for 165 ms
- ABS/ESC valve: target current is 0A, solenoid current is over than 1A
- BBS valve: target current is 0A, PWM is over than 1A
- If the valve relay is switched "ON" and the corresponding solenoid driver "OFF" under the conditions below for 200 ms
- ABS/ESC valve: target current is 0A, VVR - 4V is over than drain voltage X
- BBS: PWM is 0%, VVR - 4V is over than drain voltage X
- If the valve relay is switched "ON" and the corresponding solenoid driver "OFF" under the conditions below for 165 ms
- ABS/ESC valve: ISOL > 8.5 ± 2.5V, VVR -SOL < 0.8V
- BBS valve: VDRN > VREG * 14%
- If the valve relay is switched "ON" and the corresponding solenoid driver "OFF" under the conditions below for 200 ms
- NC: ITARGET is ON, VDRNX is high
|
| Case 3 (Solenoid valve over temperature) |
- If the solenoid valve driver ICs report over temperature status for specific time
- ABS/ESC valve: 165 ms
- BBS valve: 2s
|
| Warning Lamp |
- IEB, RBS, EBD, ABS, ESP, DBC, AVH (buzzer)
|
| Disable Condition |
Case 1 (Solenoid valve open) |
- Valve reset after Ignition "OFF" and then "ON"
|
| Case 2 (Solenoid valve short) |
- Ignition "OFF" and then "ON" after clear error
|