| DTC Strategy |
- Monitor brake oil pressure
|
- Brake fluid leak
- Faulty IEB module
- System failure
|
| Enable Condition |
- Ignition "ON"
- Auxiliary battery normal voltage (7 to 19V)
|
| Threshold Value |
- External leakage occur (If circuit pressure is less than hydraulic volume which is generated by pump)
- Internal leakage occur
- Mechanical faulty hydraulic brake circuit occur
|
| Warning Lamp |
Single Circuit Leakage |
- IEB, RBS, ABS, ESP, DBC, AVH
|
| Dual Circuit Leakage |
- IEB, RBS, ABS, ESP, DBC, AVH (buzzer)
|
| Dual Circuit Leakage |
- IEB, RBS, ABS, ESP, DBC, AVH
|
| Detecting Time |
|
| Disable Condition |
- Ignition "OFF" and then "ON" (brake pressed and released is for 3s)
|