Circuit Inspection
| Inspection Item | Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | |||
| Power inspection (EPB actuator LH ↔ Chassis ground) |
|
EPB actuator LH connector | 2 (motor +) | Chassis ground | - | Approx. 10V |
| EPB actuator LH connector | 1 (motor -) | Chassis ground | - | Approx. 10V | ||
| Open in Circuit Inspection (EPB actuator LH ↔ IEBU) |
|
EPB actuator LH connector | 2 (motor +) | IEBU connector | 13 (motor +) | Approx. below 1Ω |
| EPB actuator LH connector | 1 (motor -) | IEBU connector | 12 (motor -) | Approx. below 1Ω | ||
| Resistance inspection (EPB actuator LH) |
|
EPB actuator LH connector | 2 (motor +) | EPB actuator LH connector | 1 (motor -) | Approx. 0.2Ω |
Good
- Go to "COMPONENT INSPECTION " procedure.
No Good
- Repair open or short in circuit and then go to "Verification of Repair " procedure.