Circuit Inspection

G13665808Courtesy of KIA MOTORS AMERICA, INC.

Squib Circuit Inspection 

NOTE: If dummy and dummy adaptor are not able to be prepared, use a 2Ω resistor.
  1. Ignition "OFF".
  2. Disconnect the battery (-) cable and wait for 5 minutes or more.
  3. Remove the DSAB module and connect the dummy and dummy adapter to the DSAB module connector.
  4. Connect the battery (-) cable and ignition "ON" and wait for 30s or more.
  5. Connect KDS to Data Link Connector (DLC) and clear DTC with KDS and diagnose again.
  6. Are any DTCs stored in the system?

    Good 

    • Go to next procedure.

    No Good 

    • Carefully re-do this troubleshooting guide steps.
    • If problem still occurs, replace DSAB module and then go to "VERIFICATION OF REPAIR " procedure.
    Main Harness Circuit Inspection
    Inspection Condition (+) Probe (-) Probe Specification
    Connector Terminal Connector Terminal
    1. Ignition "OFF".
    2. Disconnect the battery (-) terminal cable from the battery, and wait at least for five minutes.
    3. Disconnect the electrical connector(s) from the concerned component.
    DSAB connector 1 (high) SRSCM connector 23 (high) Approx. below 1Ω
    DSAB connector 2 (low) SRSCM connector 24 (low) Approx. below 1Ω
    DSAB connector 1 (high) Chassis ground - ∞ (infinity)Ω
    DSAB connector 2 (low) Chassis ground - ∞ (infinity)Ω
    1. Connect the SRSCM main connector.
    2. Connect the battery (-) terminal cable to the battery.
    3. Ignition "ON".
    DSAB connector 1 (high) Chassis ground - Fig.1
    DSAB connector 2 (low) Chassis ground -
    G13665810Courtesy of KIA MOTORS AMERICA, INC.

    Good 

    • Carefully re-do this troubleshooting guide steps.
    • If problem still occurs, replace SRSCM and then go to "VERIFICATION OF REPAIR " procedure.

    No Good 

    • Carefully re-do this troubleshooting guide steps.
    • If problem still occurs, replace SRSCM main harness and then go to "VERIFICATION OF REPAIR " procedure.