Circuit Inspection
WARNING: This page is about a different variant/trim than selected.
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
TCU | 6 (power) | Chassis ground | - | B+ |
|
TCU | 2, 3 (ground) | Chassis ground | - | Approx. below 1Ω |
|
TCU | 2 (input speed sensor power) | Chassis ground | - | Approx. 9V (reference Fig.1) |
|
TCU | 1 (input speed sensor signal) | Chassis ground | - | Approx. 0V (reference Fig.1) |
Good
- This fault is a temporary fault caused by failure to clear the fault code or by poor contact with the connector. Overall, check connectors for slackness, poor contact, bending, corrosion, contamination, deformation or damage. If the problem continues, replace the DCT assembly then go to "TCU Neutralization" and "Air bleeding" of S/W management and perform the "VERIFICATION OF REPAIR " procedure.
No Good
- After repair or replacement if necessary, go to "VERIFICATION OF REPAIR " procedure.
- After checking the circuit for open circuits or short circuits and repairing them, go to "VERIFICATION OF REPAIR " procedure.