Component Inspection
EVP Relay Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
EVP relay (component side) | 3 (relay power) | EVP relay (component side) | 5 (relay control) | Approx. 80Ω (68°F) |
Good
- Go to "EVP Inspection" procedure.
No Good
- Carefully re-do troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the EVP relay and go to "Verification Of Repair " procedure.
EVP Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
| Connector | Terminal | Connector | Terminal | ||
|
EVP connector | 1 (motor (+)) | Chassis ground | - | Fig. 1 |
| EVP connector | 2 (motor (-)) | Chassis ground | - | ||
Good
- Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.
- If the EVP or EVP relay is normal and the symptoms persist, replace the BBVPS and perform the "Verification Of Repair " procedure.
No Good
- Carefully re-do troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the EVP and go to "Verification Of Repair " procedure.