| DTC Strategy |
|
- Poor connector connection
- Faulty BBVPS
|
| Enable Condition |
- Normal battery voltage (9.5 to 16.5V)
- Ignition "ON"
|
| Threshold Value |
- 1) Save maximum vacuum sensor data (A) when master pressure is under 2bar for 1s, save minimum vacuum sensor data (B) when master pressure is over 15 bar for 1s. (A) and (B) with no change of vacuum sensor signal.
- 2) Monitoring dynamic changes (75mmHg for 1ms) of vacuum sensor signal if the change is more than 150 count for 2s and non control status. *Non control status: BLS "OFF" and MCP <7bar
|
| Detecting Time |
- In control/non-control: 300ms
|
| Warning Lamp |
|
| Disable Condition |
- After ignition off and then on, (supply voltage is 4.75 to 5.25V) and (sensor output voltage is 0.25 to 4.85V) status is over 60ms
|