Circuit Inspection
| Inspection Condition | (+) Probe | (-) Probe | Specification | ||
|---|---|---|---|---|---|
| Connector | Terminal | Connector | Terminal | ||
|
SML | 1 (power) | Chassis ground | - | B+ |
|
SML | 3 (LED green) | Mood lamp unit | 9 (LED green) | Approx. below 1Ω |
| SML | 2 (LED red) | Mood lamp unit | 8 (LED red) | Approx. below 1Ω | |
| SML | 4 (LED blue) | Mood lamp unit | 10 (LED blue) | Approx. below 1Ω | |
| SML | 5 (DIAG wire) | Mood lamp unit | 21 (DIAG wire) | Approx. below 1Ω | |
Good
- Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage, and carefully re-do this troubleshooting guide steps.
- If no problems were found with the circuits or connectors, replace the mood lamp unit and go to "VERIFICATION OF REPAIR " procedure.
No Good
- Carefully re-do this troubleshooting guide steps.