Monitor DTC Status
| Inspection Condition | Inspection Procedure | Reference |
|---|---|---|
|
|
Fig.1 |
Active Fault
- Fault is intermittent caused by poor contact in the sensor's and/or Control module's connector or was repaired and Control module's memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
- Repair or replace as necessary and then go to "SYSTEM INSPECTION " procedure.
- If the DTC is erased, check for proper operation. If problem is corrected, replace SCC (FCA) and then go to "SYSTEM INSPECTION " memory was not cleared. Go to "VERIFICATION OF REPAIR " procedure.
* In a case of replacing SCC (FCA) module, require to set the "Variant Coding" by KDS.
History/Pending Fault
- This fault was repaired and SCC (FCA) module memory was not cleared. Go to "VERIFICATION OF REPAIR " procedure.