Monitor KDS Data
| Inspection Condition | Inspection Procedure | Reference |
|---|---|---|
|
|
Fig.1 to 2 Table1 |
THRESHOLD VALUE SPECIFICATION
| Item | Threshold Value |
|---|---|
| Charging Voltage | 1 - 12V |
| Charging Current | 0.1 - 4A |
| Charging Power | 1 - 15W |
| Battery Voltage | 9 - 16V |
| ACC Input Voltage | 9 - 16V |
| ACC | ON: Chargeable/OFF: No charging |
| Charging Status LED (Yellow) On/Off | ON: Charging/OFF: No charging |
| Charging Status LED (Yellow) Blinking | ON: Metal material detection or heat generation or position deviation/OFF: Normal |
| Charging Status LED (Green) Blinking | ON: Charging complete |
| Frequency Interference with SMK | ON: No charging (Door open or SMK in operation)/OFF: Normal (Chargeable) |
| Charging Status | Charging: Charging normally/OFF: No charging |
Table1) Threshold Value of Current Data
Good
- Fault might be intermittent and caused either by poor contact in connectors or wiring harness, or it has been repaired and control module memory is not cleared yet. Thoroughly check terminal of battery, all connectors (and connections) for looseness, bending, corrosion, contamination, deterioration, and/or damage.
- Repair or replace as necessary and go to "VERIFICATION OF REPAIR " procedure.
No Good
- Go to "WIRING INSPECTION " procedure.