| DTC Strategy |
- Accumulator charging pressure monitoring
|
- Faulty bleeding process
- Leakage on hydraulic pipe lines
- Faulty pressure sensor
- Faulty PSU motor
|
| Enable Condition |
|
| Threshold Value |
- A failure is detected if any condition below is satisfied during HPA charging
- HPA pressure is less than 100bar for 20s
- HPA pressure is less than 140bar for 30s
- HPA pressure is less than 157bar for 45s
|
| Warning Lamp |
- Brake (EBD), ABS, ESC, AVH warning indicator lamp "ON"
- Buzzer "ON"
|
| Disable Condition |
- Ignition "OFF"/"ON" and Brake Pressed and Released for more than 3s
|