DTC Information: DTC Detecting Condition
WARNING: This page is about a different variant/trim than selected.
| Item |
Detecting Condition |
Possible Cause |
| DTC Strategy |
Case1 |
- TPS adaptation Lower position check
|
- Poor connection or damaged connector
- Faulty ETC motor
|
| Case2 |
- TPS adaptation error low return spring check
|
| Case3 |
- TPS adaptation upper position check
|
| Case4 |
- TPS adaptation error upper return spring check
|
| Case5 |
- TPS start check error in spring check
|
| Case6 |
- TPS start check error in limp-home-check
|
| Enable Conditions |
Case1 |
- During TPS adaptation
- TPS setpoint is equal 1.991°
|
| Case2 |
|
| Case3 |
- During TPS adaptation
- TPS setpoint is equal 20.001 °
|
| Case4 |
|
| Case5 |
- During TPS start check
- TPS setpoint is equal 17.003°
|
| Case6 |
- During TPS start check
- No engine start condition
|
| Threshold Value |
Case1 |
- Throttle position for the lower return spring check is not reached within a limit maximum time (Difference between throttle position and setpoint is higher than 0.5°)
|
| Case2 |
- When ETC power stage is off, Throttle can not return by spring power in the limp-home position within a limit maximum time (Difference between Throttle position and adapted voltage in limphome position is higher than 0.18V)
|
| Case3 |
- Throttle position for the upper return spring check is not reached within a limit maximum time (Difference between throttle position and setpoint is higher than 0.5°)
|
| Case4 |
- When ETC power stage is off, Throttle cannot return by spring power in the limp-home position within a limit maximum time (Difference between Throttle position and adapted voltage in limphome position is higher than 0.18V)
|
| Case5 |
- Throttle flap cannot reach the setpoint within the hysteresis within a limit maximum time (Difference between throttle position and requested position is higher than 0.5°)
|
| Case6 |
- When ETC power stage is off, Throttle cannot return by spring power in the limp-home position within a limit maximum time (Difference between Throttle position and adapted voltage in limphome position is higher than 0.18V)
|
| Diagnostic Time |
|
| MIL ON Condition |
|