LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2020 >> Soul GT Line Turbo >> Repair and Diagnosis >> External Pages >> Different car >> Section 106 (Engine Control System Diagnosis - 2.0L (5 Of 6)) >> DTC P2006-00: Intake Manifold Runner Control Stuck Closed (Bank 1) >> Wiring Inspection >> Circuit Inspection

Circuit Inspection

WARNING: This page is about a different car, the 2021 Kia Soul. However, it is still accessible from the selected car via links, so may be relevant.
G13292174Courtesy of KIA MOTORS AMERICA, INC.
G13292175Courtesy of KIA MOTORS AMERICA, INC.
Inspection Condition (+) Probe (-) Probe Specification
Connector Terminal Connector Terminal
  1. Ignition "OFF".
  2. Disconnect the electrical connector (s) from the concerned component.
  3. Ignition "ON".
VCM connector 1 (motor +) Chassis ground - Approx. 11.5V
VCM connector 2 (motor -) Chassis ground - Approx. 11.2V
VCM connector 3 (ground) Chassis ground - 0V
VCM connector 4 (signal) Chassis ground - Approx. 4.8V
VCM connector 5 (power) Chassis ground - Approx. 5V
  1. Ignition "OFF".
  2. Disconnect the electrical connector (s) from the concerned component.
VCM connector 1 (motor +) Chassis ground - ∞ (infinity)Ω
VCM connector 2 (motor -) Chassis ground - ∞ (infinity)Ω
VCM connector 3 (ground) PCM connector 54 (ground) Approx. below 1Ω

Good 

No Good