Squib Circuit Inspection
- Ignition switch "OFF".
- Disconnect battery (-) cable and wait at least for one minute.
- Remove the curtain airbag-passenger and connect the dummy and dummy adaptor to curtain airbag-passenger harness connector.CAUTION: If dummy and dummy adaptor are not able to be prepared, use a 2Ω resistor.
- Connect battery (-) cable and turn the ignition switch "ON" and wait for 30 sec.
- Connect KDS to Data Link Connector (DLC) and clear DTC with KDS and run the diagnostics again.
- Has any DTCs stored in the system?
YES
- Go to "MAIN HARNESS CIRCUIT INSPECTION " procedure.
NO
- Carefully re-do this troubleshooting guide steps.
- If problem still occurs, replace Curtain Airbag-Passenger and then go to "VERIFICATION OF VEHICLE REPAIR " procedure.