Controls the cooling fan motor voltage depending on the duty output from the ECU (Freq.: 300Hz). [Signal from the ECU to the PWM (SI: 300Hz)]

G12932247Courtesy of KIA MOTORS AMERICA, INC.
SI Duty Motor Voltage (V) Variation (V)
10% 0 ±0.5
30% 4.1
60% 8.2
70% 9.57