| 1 |
Door open |
Door Close |
LED OFF |
| 2 |
Foreign object detection |
No foreign object |
Orange LED OFF |
| 3 |
Over current greater than 4.5A |
Normal current |
Orange LED OFF |
| 4 |
Internal temp. greater than 70°C (158°F) |
Internal temp. less than 65°C (149°F) |
Orange LED OFF |
| 5 |
Low voltage (8.5 V or less)/high voltage (16.5 V or higher) detected |
Return if detected as 9.0 V to 16.0 V |
LED OFF |
| 6 |
Reverse voltage detection |
Reverse voltage release |
LED OFF |
| 7 |
Mobile phone notification function (leave mobile phone unattended for 1 minute or when door is opened after key off) |
Remove a cell phone |
Release of instrument cluster warning statements (Approx. 4~5 s) |