DC-Motor (EWGA)
WARNING: This page is about a different variant/trim than selected.
| Supply Voltage Range | Max Current |
|---|---|
| 9~16V | 7.05A ± 15% |
| Item | Resistance |
|---|---|
| Normal Parameter At 20°C (68°F) | 1.44 ~ 1.96 Ω |
| Position | Output Voltage (V) | Operating Angle[°] |
|---|---|---|
| Mechanical Close end stop Position (MCP) | 4.8 | 0 |
| Electrical Close end stop Position (ECP) | 3.8 | 25.6 |
| Electrical Open end stop Position (EOP) | 1 | 97.2 |
| Mechanical Open end stop Position (MOP) | 0.5 | 110 |