Repair Procedures: Replacement
WARNING: This page is about a different variant/trim than selected.
- Discharge refrigerant from refrigeration system.
- Replace faulty tube or hose.CAUTION: Cap the open fittings immediately to keep moisture or dirt out of the system.
- Tighten joint of bolt or nut to specified torque.CAUTION: Connections should not be torque tighter than the specified torque.
Part tightened N.m kgf.m lb-ft Condenser - Discharge hose 3.9~5.9 0.4~0.6 2.9~4.3 Condenser - Liquid tube Compressor - Discharge hose 3.9~5.9 0.4~0.6 2.9~4.3 Compressor - Suction hose Expansion valve - Evaporator 7.8~11.7 0.8~1.2 5.7~8.6 - Evacuate air in refrigeration system and charge system with refrigerant.
Specified amount 550 ± 25g (19.4 ± 0.88 oz.)
- Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
- Inspect A/C operation.