LEMON Manuals: Even more car manuals for everyone
Home >> Kia >> 2016 >> Optima SX Limited >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 34 (Air Conditioning System (HEV)) >> Ambient Sensor >> Repair Procedures >> Inspection

Repair Procedures: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. Ignition "OFF"
  2. Disconnect ambient temperature sensor.
  3. Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.
    Fig 1: Checking Resistance Of Ambient Temperature Sensor Between Terminals 1 And 2
    G11818485Courtesy of KIA MOTORS AMERICA, INC.
    AMBIENT TEMPERATURE SENSOR SPECIFICATIONS

    Ambient temperature [°C(°F)] Resistance between terminals 1 and 2 (kΩ)
    -30(-22) 480.41
    -20(-4) 271.21
    -10(14) 158.18
    0 (32) 95.10
    10 (50) 58.80
    20 (68) 37.32
    30(86) 23.76
    40(104) 16.13
    50(122) 10.95
  4. If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
  5. If the problem is corrected, replace the ambient temperature sensor.